Troubleshooting, Caution – Lincoln Electric IM806 WELDMARK 225 User Manual

Page 31

Advertising
background image

E-3

TROUBLESHOOTING

E-3

WELDMARK 225

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Engine will not go to high idle when
using auxiliary power.

Engine will not crank or is hard to
crank.

Engine shuts down.

Engine does not develop full power.

Engine is hard to start.

No auxiliary power.

1.

No voltage signal from the
current sensor.

2.

Auxiliary power load less than
100 to 150 watts.

3.

Faulty P.C. Board.

1.

Battery will not hold a charge.
Faulty Battery.

2.

No or insufficient charging
current.

3.

Loose battery cable
connection(s).

1.

Out of fuel.

2.

Low oil level.

1.

Fuel filter clogged.

2.

Air filter clogged.

1.

Spark plugs do not have
specified gap.

2.

Spark plugs are fouled.

1. GFCI Receptacle may have

tripped. Follow

GFCI Receptacle

Testing and Resetting Procedure

in the MAINTENANCE section of
this manual.

2. Open breakers may need to be

reset.

3. Faulty receptacle.

4. Faulty auxiliary circuit wiring.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Authorized Field
Service Facility.

Advertising