LT Security PTZ217X12 User Manual User Manual

Page 13

Advertising
background image

User Manual of 4-inch High Speed Dome

4

E4

Cable is connected and data can be normally
received, but the settings of address and
command are incorrect

E5

Cable is connected, but the received data does
not comply with the requirements of Manchester
code


Time Task
A time task is a preconfigured action that can be performed automatically at a specific date and
time. The programmable actions include: preset 1-8, pattern 1-4, patrol 1-4, pan scan, tilt scan,
random scan, frame scan, panorama scan, day/night mode or none.
Zone
A zone is a user-defined area. The dome provides eight zones, each with configurable label. If the
dome has dwelled at a zone without receiving any command over 4 minutes, this feature will enable
the dome to perform panorama scan within the zone.
Password
The dome features password protection to prevent unauthorized changes to the dome settings.
Camera Title
Title text is the label used to identify the camera viewed on the monitor. Up to 15 characters can be
used for a title
RS-485 Failure Diagnostics
In the presence of failure at the transmitting and receiving terminals of RS-485 communications, the
speed dome is capable of performing self-test and detecting the fault results which will be displayed
on the screen.
Soft Baudrate
The baudrate of dome can be configured by the menu without need of DIP switch settings.

Advertising