Nature Power 3000W Pure Sine Inverter Charger (38330) User Manual

Page 11

Advertising
background image

 

Page 11

 

 

 

Green

LED

ON

(flashing)

Pass-Through Mode (AC mode). Battery Charging is in progress.

Remote LCD Display shows:

- Battery DC Voltage and charging current

- AC Input Voltage and Current

e.g.

AC: 120V 20A DC: 12.0V 50A

Press ‘+’ or ‘-‘ key to check charging stage.

e.g

. Charge Stage ABS

Press ‘+’ or ‘-‘ key to check AC Input Power.

e.g

. System Power 2.4 KW

Fault

Red

LED ON

(solid)

Unit has shutdown. Display shows error code and error message.

- Low battery shutdown

e.g.

FAULT: E01 Low Battery

Push Button Functions on Unit

A beeping sound will occur every time that any button on the unit is triggered.

Button

Function

Power Turns unit On/Off. Press and hold for 1 second to turn unit On/Off

Reset Reset the unit: Press once to reset the unit. This may be required when an error

is detected on the unit

Push Button Functions on Remote Display

A beeping sound will occur every time any button on the unit is triggered.

Button

Function

O

Turns LCD display On/Off. Press and hold for 2 seconds to turn display On/Off.

Display shows unit model number and revision.

e.g.

Nature 38330

Power

REV 1.1

Enter

Save the selected setting or go to the next stage

+

Scroll up on the menu

-

Scroll down on the menu

EXIT

Exiting or entering the feature setting mode

Understanding the Charger Functions

Three-Stage Charging:

The Three-Stage Charging algorithm has a Bulk, then Absorption and then Float sequence.

During the Bulk stage, the battery accepts the maximum constant current from the charger. In

the Absorption stage, the battery voltage is held to constant voltage and the charging will

slowly reduce. In Float stage, the charger continuously produces voltage at a lower level to

fully top up the battery and maintain the battery in a fully charged state.

The charger will automatically restart the charging cycle in Bulk stage if the battery is

discharged to 12.5V. Also, after seven days, the charger will automatically restart the

recharging cycle to refresh the battery.

Battery Type:

Three types of battery setting (GEL, AGM and Flooded) are available. See reference battery

charging voltage as shown:

Battery Type

Absorption

Float

Equalization

GEL

14.4 V

13.8 V

N.A.

AGM

14.3 V

13.45 V

N.A.

Flooded

14.4 V

13.5 V

16.0 V

Equalize the Flooded Battery:

For Flooded battery type, equalization mode is available. Use the following procedure to

equalize the flooded battery. See also section 5 on setting EQ mode for flooded battery.

DANGER: Explosion Hazard. The flooded battery generates explosive gases

during equalization. Follow all the battery safety precautions listed in the manual.

CAUTION:

Risk of Battery and Equipment damage. Only a Flooded lead-acid battery can

Advertising