To begin, sufficient seed must be placed in the hopper above the meter to be
calibrated to ensure full flow during the calibration procedure. Measure and
record the weight of the calibration bucket and place under the meter. The
calibration requires meter revolution input and speed input. A separate calibration
must be done for each meter.









Procedure:

Step 1: Having Selected Meter (1, 2 or 3) Calibration,
“Target 10.0lb/ac” is displayed. Press the Toggle
Button.




Enter your desired “target” application rate by using the
Toggle Button and Selector Knob to edit. Once the
desired target application rate is set, press the Enter
Key
to accept. In the example below “Target” is set for
100lb/ac.



As stated on the screen: set the gearbox on the implement to a setting of 100
using the increase/decrease switch on the side mounted control box and PRIME
THE METER
to ensure full flow at the beginning of the calibration.

NOTE: The product metered during priming is not used for calibration. Do
not include this product when obtaining the calibration weight.