3 low alarm point, 4 weight / rev – Seed Hawk GRANULAR AND LIQUID TANKS 2009 User Manual

Page 55

Advertising
background image

Seed Hawk Manual

Granular and Liquid Tanks

Page 53

9.6.3 Low Alarm Point


This is the minimum meter RPM the monitor will recognize. If the meter RPM falls
below this setting an alarm will sound and must be acknowledged if the condition
is left to continue. The default low alarm point value is 0.5 RPM. If this value is to
be changed, press the SELECT button and “0.5RPM” will be highlighted and can
be changed using the up/down arrow keys. Once the desired value is on the
screen press the SELECT button again and the highlight bar will move to the
“Weight/Rev” bar. When seeding Canola or inoculants at slow speeds (less than
4mph) slow speed alarm maybe triggered.

 
 
 
 
 
 
 
 
 
 
 
 

9.6.4 Weight / Rev


Monitor calculates and enters this value after calibration is completed.
Default is 0 for a new system.

 
 
 
 
 
 
 
 
 
 
 
 
 
 


Advertising