Direct ip via ethernet – Spectra Precision ProFlex 800 Web Server User Manual
Page 26

22
– The rover being a client, enter the information (
Connect
Now, Address, Port, Login, Password) allowing it to
connect to the base (the server) from which it is
supposed to receive corrections. The login and
passwords are required only if the server demands
authentication (e.g. SpiderNet). In that case, the
message “$GPUID,<login>,<password> will be
generated automatically and sent to the server when
clicking on
Configure.
Enable
Connect Now to allow the receiver to establish
the connection right after you have clicked on
Configure.
• At the bottom of the page, in the
Differential Port pane,
select the
Automatic option to let the receiver detect the
incoming differential stream automatically.
NOTE:
Automatic is the recommended choice for the
Differential Port setting because in this case, you don’t
need to define the ports receiving the two possible
differential streams.
• Click on the
Configure button to let the Web Server load all
your new parameters to the receiver. You just have now to
define the output messages (see Defining Output
Messages on page 30).
Direct IP Via
Ethernet
• First, click on the
Connections> Ethernet submenu.
• Set the following Ethernet parameters to allow the receiver
to access the network through its Ethernet port:
–
DHCP: Enabling this option means the local network to
which the receiver is connected will automatically
allocate a dynamic IP address to the receiver. If this
option is disabled, you need to define the receiver’s
static
IP address, and give information about the local
network (
Subnetwork Mask and Gateway). You may need
to be assisted by a network expert -or IT Manager- to
define these parameters (as well as the three
parameters below).
RTK Corrections
Ethernet
ProFlex 800
Base
IP address
or server name
(Client)
Internet