Star Water Systems Convertible Jet Pump Quick Start Guide User Manual

Page 2

Advertising
background image

CAUTION: All pumps must be primed (filling the cavity with water) before they are first

operated. This may take several gallons of water, as the suction line will be filled in addition to

the pump cavity.

2. Fill pump cavity with water until full and replace

priming plug. (

Fig. 2)

3. Tighten flow control screw completely by turning

clockwise, then loosen two turns. Now start the

pump. (

Fig. 3)

4. If pump is properly primed, pressure will

quickly build and register on the gauge

mounted directly on the pump body. If

pressure does not build repeat priming

operation. All air must be vented from the

drive and suction pipes as well as the body

before the pump will prime. The pump body

may need to be filled several times in order to

achieve the prime. (

Fig. 4)

Pressure gauge

5. With pump operating at high pressure, open

two or more faucets and slowly unscrew

the flow control screw until maximum flow

is obtained. This steady pressure will be

minimum operating pressure and should agree

with the pressure shown below. The flow

control screw diverts the proper amount of

water to operate the ejector. (

Fig. 5)

HP

Pressure Setting

1/3

1/2

3/4

1

24 PSI

27 PSI

38 PSI

46 PSI

The correct control valve setting will depend on the

type of well installation and pressure switch setting

for the particular pump.

NOTE: If the pump is being used for shallow well

applications, the flow control screw should be set in

the full open position.

IMPORTANT: If the pump fails to prime within

five minutes:

Turn power off at the breaker box. Look for leaks

or a milky color in the discharged water, which

indicates an air leak. Re-prime if necessary,

following steps 1 through 5 above. Reset breaker at

the breaker box. All connections must be water and

air tight in order for pump to operate.

PRIMING

Copyright © 2011 Star Water Systems. All rights reserved.

1. Remove the 1/2 in.priming plug. (

Fig. 1)

4. Thread in priming plug and then open optional

ball valve if installed (see page 5) by turning

handle to line up with the pipe.

(Fig. 4)

2. Slowly fill pump cavity until water comes out of

air relief hole on top of the pump. (

Fig. 2)

3. Replace air relief plug and continue adding

water to pump cavity until water reaches the

top of the priming plug.

(Fig. 3)

Water

level in

pump

cavity

5. Turn on breaker to start pump

Priming plug

with pressure

gauge

Air relief plug

1. Remove the 1/2 in. priming plug with pressure

gauge and air relief plug. (

Fig. 1)

IMPORTANT: If the pump hums instead of pumping or turns off repeatedly, shut pump off immediately.

Check voltage. Make sure your incoming voltage matches the pump wiring voltage. See wiring guide in the

instructions.

6

Shallow Well Application Only

Deep Well Application Only: