PUMP ELECTRICAL CONNECTIONS

Wiring the pressure switch

CAUTION: Make certain that the power source

matches the pump requirements. This pump has

a dual voltage motor and can run on either 115 V

or 230 V.

Pump is pre-set at the factory to run on 230 V.

1. To change pump voltage, remove the square

voltage switch cover at the top of pump and

move the voltage switch as shown.

1

115 V

Setting

230 V

Setting

PUMP ELECTRICAL CONNECTIONS

2. To connect the pressure switch, remove the

switch cover and insert an electrical wire

strain relief (not included) into the opening in

the side of the pressure switch.

Wire from

motor

Pressure

Switch

Strain

Relief

Wire from

motor

Wire from

power

supply

3. Thread the electrical wire (not included) from

the power supply through the strain relief and

tighten both screws on the strain relief. Do

not crush wire.

2

3

Wire from

motor

Wire from

power

supply

Outside

terminal

Outside

terminal

Wire

from

motor

Wire from

power

supply

Ground Screws

5. Connect the green ground wire from the

power supply to the remaining green ground

screw in the pressure switch and re-attach

the pressure switch cover.

4. Connect the two wires from the power supply

to the two outside terminals on the pressure

switch.

4

5

PUMP PRIMING AND STARTUP

PRIMING

CAUTION: All pumps must be primed

(filling the cavity with water) before they are

first operated. This may take several gallons

of water, as the suction pipe will be filled in

addition to the cavity of pump.

1. Remove pipe plug or pressure gauge (not

included) at the top of the discharge tee and

the vent plug in front of the discharge tee.

Vent plug

Priming plug

or pressure

gauge

Suction

Pipe

1

2. Slowly fill the discharge tee with water until

water overflows the vent plug opening.

Replace the vent plug loosely.

NOTE: It will take several minutes to fill pump

and suction pipe completely.

Discharge Tee

Vent plug

Vent plug

opening

Priming plug

opening

2

3. Be sure entire suction pipe is filled when

priming. Depending on the length of suction

pipe, many gallons will be needed to fill the

entire system.

Suction

Pipe

3