USGlobalsat TR-206 User Guide User Manual

Page 60

Advertising
background image

TR-206

page 60

Command

Code Word Concerning Parameter

Ping

PI

=tolerance time of GPS fix

Periodic report

PR

=report interval

Motion moving

MM

=moving report interval

Motion static

MS

=moving static interval

Link Server

LI

Command format:
“password,simple command,simple command,simple command”

Note:

Do include spaces between the commas. Otherwise, the

TR-206 would not be able to distinguish what is the command.

Example 1: Ping the TR-206 and set the tolerance time of GPS

fix as 3 minutes. The password is 520JX

The command is

“520JX,PI=180”

Example 2: Switch the mode of the TR-206 to motion mode. Set

the moving report interval as 30 seconds and static report

interval as 30 minutes. The password is 7777.

The command is

“7777,MM=30,MS=1800”

Example 3: Make the TR-206 to report periodically with the

interval of factory value. The password is VICTORY.

The command is

“VICTORY,PR”