STATIC ATTIC VENTILATORS

INSTALLATION INSTRUCTIONS

Models: STV51, STV51GV, SBV603, SBV603GV, SBV61, SBV40GV

These roof-mounted units are designed for attics of average size and operate most efficiently if air intakes are located

around the eaves. For larger attics, use two or more units. An adequate amount of air intake is required for each unit.

1.

Place the unit on top of the shingles, as close to the center of the roof and as near to the

ridge line as possible. For neat installation, the low profile housing on the unit should be

visible only on one side of the roof. This will require that the unit be moved down

slightly from the ridge. When this position is established, locate a centerline directly

between two rafters and drill a hole through the roof, from the inside. This hole will be

used as a center for the following operations.

2.

Draw a circle or square on the roof (refer to chart below for opening size), using the

drilled hole as the center, and cut the appropriate size hole in the roof.

3.

With the top of the unit parallel to the ridge line, slide the flange up under the shingles.

It may be necessary to remove some additional roofing material and fasteners around

the unit for it to fit snugly. Select an appropriate roofing sealant for the construction

material (refer to chart below), and apply a generous amount between the flange and

shingles, approximately ½” from the outer edge. Secure with approved roofing nails, or

staples with a minimum 1” penetration, and a maximum 4” space between each nail or

staple.

LOCATING THE STATIC VENT

CUTTING THE HOLE

INSTALLING THE VENT

STV-51 / STV-51 GV

Square top aluminum / galvanized

16.5” x 17.5“

8 .125”

51 sq in

SBV 603 / SBV 603 GV

Slant back aluminum / galvanized

16“ x 20”

8.125”

51 sq in

SBV61

Slant back plastic

17“ x 18”

9”

61 sq in

SBV 40 GV

Slant back galvanized

14“ x 16.75”

7.25”

40 sq in

MODEL

DESCRIPTION

BASE

OPENING

NFA

STV51

SBV603

SBV61

SBV40GV