3djlqj)hdwxuh, Erxw$xwrpdwlf3djlqj – ADT Security Services K5309V2 User Manual

Page 26

Advertising
background image

– 26 –

3DJLQJ)HDWXUH

$ERXW$XWRPDWLF3DJLQJ

Your system may be set up to automatically send alert messages to a pager as certain
conditions occur in your system.

•

The following events can be programmed by your installer to be sent to the pagers:
arming, disarming

†

, alarms, and trouble conditions. († reports when arming/disarming

from a touchpad using a security code; auto-arming/disarming, arming with assigned
button, and keyswitch arming do not send pager messages.)

•

You can also program the system to send an automatic pager message to alert you
in the event that someone has not arrived home (disarmed the system) within a
defined period of time (see the Scheduling section for details on programming a
“latch key report”).

•

Your installer programs the pager phone numbers and reporting events.

•

The pager message consists of a 7-digit system status code that indicates the type of
condition that has occurred.

•

An optional, predefined 16-digit character string can precede the 7-digit system
status code; these characters can consist of a PIN no., subscriber account no., or any
additional data that you may wish to have sent to the pager.

•

The pager display format is as follows:

3-digit Event Code

И

И

Optional 16 digits

Ж

Ж

AAAAAAAAAAAAAAAA – BBB – CCCC

Е

Е

4-digit User or Zone No.

A =

B =

C =

Optional 16-digits for
Account numbers,
PIN numbers, or any
other data;
programmed by the
installer, if required.

A 3-digit code that

describes the event
that has occurred
in your system
(see for event
codes table below)

A 4-digit User or Zone number, depending on the type of
event that has occurred, where:

•

alarms and troubles display zone number

•

arming/disarming (opens/closes) display user number

The first 2 digits are always “00” (e.g., 0004 represents
zone or user number 4), and, single-digit user or zone
numbers are always preceded by a zero.

The 3-digit Event Codes (BBB) that can be displayed are:

911 =

811 =

101 =

102 =

Alarms.

The 4-digit number
(CCCC) following this
code is the zone number
that has caused the
alarm.

Troubles.

The 4-digit number
(CCCC) following this
code is the zone number
that has caused the
trouble.

Open

(system disarmed).

The 4-digit number
(CCCC) that follows
this code is the user
number
that has
disarmed the system.

Close

(system armed).

The 4-digit number
(CCCC) that follows
this code is the user
number
that has armed
the system.

Examples of typical 7-digit pager displays follow.

Ex. 1

.

³

= R eporting of an alarm (911) caused by a fault on zone 4 (0004).

Ex. 2.

³ = Reporting of a closing–system arming (102)– by user 5 (0005).