EMO‐3000

 

Operation and Programming Manual 

 

 

 

28 

      
 

When the desired variable is moves to the arrow, select F4 = PROGRAM. The DM‐3000 then asks for the 
pass code.   

ENTER  PASS  CODE = XXXX 

The code is 4146.  

Key in the correct variable value and Enter with F6.  

The Limit Rules are set up so that by entering one of four two‐number combinations for each of the four 
limits, you can select the variable that determines the operating function according to the table below.  

11 ‐‐‐ Total Limit for A input 

12 ‐‐‐ Flow Rate Limit for A input 

13 ‐‐‐ Ratio Error Limit for A 

 

21 ‐‐‐ Total Limit for B input 

22 ‐‐‐ Flow Rate Limit for B input 

23 ‐‐‐ Ratio Error Limit for B 

 

2 = RATIOS 

    *  * * RATIOS                    * * * CH = 003  

‐‐‐‐>   RATIO  1  +/‐% 

=   XXXXX. 

 

RATIO  2  +/‐% 

=   XXXXX. 

 

RATIO  3  +/‐% 

=   XXXXX. 

 

RATIO  4  +/‐% 

=   XXXXX.           

 

F1 = ESC 

F2 = PGUP    

F3 = PGDN    

F4 = PRG 

 

 

 

 

 

 

 

 

The Ratios screen allows you to set the error percentage at which the Limits turns on, if the EMO 3000 is 
in Ratio operating mode. The calculation for the actual Ratio is: input A/input B. The Ideal Ratio is strictly 
a programmable point the desired ratio holds. Therefore, the percentage of error between the Actual 
and Ideal Ratio can control the Limit outputs if you program it that way. For example, if you program the 
Ideal Ratio to 2 (2 to 1 ratio), and the Actual Ratio measured is 2.2, the percentage of error between the 
two is 10%. If the Limit Rule is set for Ratio and you program the Ratio error percent for 10% or less, the 
limit output turns ON. 