EMO‐3000

 

Operation and Programming Manual 

 

 

 

43 

      
 

USED IN: 

 

PID mode. 

RELATED VARIABLES: 

 

A_KD/A_KP/A_KI 

HEX ADDRESS: 

 

00DE HEX  ‐‐‐‐>  SAME ADDRESS AS IN EMO‐2000 

BYTES: 

 

2 Bytes        DEFAULT: 210 

ASC form COMMAND: 

 

reading = 123; writing = 523; E and N both have the same effect 
value. By adding /XXcr, where XX is color number (example: 
#01E113/12cr), the Gain factor for the color 12 is returned. 
Omitting /XX returns 0. 

mA Scaler for PID  

The milli amps scaler is used for scaling 0 ‐ 20 mAmp analog signal input. Each milli amp above the milli 
amps in offset represents a certain amount of requested flow in engineering units or Hertz. 

USED IN: 

 

PID mode. 

RELATED VARIABLES: 

 

mA’ offset 

HEX ADDRESS: 

 

01B3 HEX  ‐‐‐‐>  SAME ADDRESS AS IN EMO‐2000 

BYTES: 

 

2 Bytes        DEFAULT: 21 cc/m per mA 

ASC form COMMAND: 

 

reading = 126; writing = 526; E returns the engineering 
units/mA; N returns Hz/mA’s.  

mA In Offset  

Used to even out sources that do not deliver exactly 4.00mA’s. In practice, it replaces a adjustment 
potentiometer. 

USED IN: 

 

PID mode. 

RELATED VARIABLES: 

 

mA’ scaler 

HEX ADDRESS: 

 

00E6 HEX  ‐‐‐‐>  NEW VARIABLE 

BYTES: 

 

2 Bytes        DEFAULT: 825 (4.02mA) 

ASC form COMMAND: 

 

reading = 124; writing = 524; E returns the mA’s value; N returns 
counts.  