Example:

The present load limit is at 100W, and the wheel knob status is at
normal, the SP-<cr> message is sent to the power supply, the load
limit of which will become 099W.

*SUM

Function:

Set the maximum voltage limit value.

Syntax:

SUM<cr>

HEX = 53 55 4D 0D

Explain:

When the message of SUM<cr> is sent to the power supply from
computer, the power supply will set the voltage limit to the maximum
immediately.

Example:

The present voltage limit is at 20V, the SUM<cr> message is sent to
the power supply, the voltage limit of which will become 40V.

*SIM

Function:

Set the maximum current limit value.

Syntax:

SIM<cr>

HEX = 53 49 4D 0D

Explain:

When the message of SIM<cr> is sent to the power supply from
computer, the power supply will set the current limit to the maximum
immediately.

PSP SERIES

USER MANUAL

35

Example:

The present current limit is at 2.50A, the SIM<cr> message is sent to
the power supply, the current limit of which will become 5.00A.

*SPM

Function:

Set the maximum load limit value.

Syntax:

SPM<cr>

HEX = 53 50 4D 0D

Explain:

When the message of SPM<cr> is sent to the power supply from
computer, the power supply will set the load limit to the maximum
immediately.

Example:

The present load limit is at 100W, the SPM<cr> message is sent to the
power supply, the load limit of which will become 200W.

*KF

Function:

Set the wheel knob to Fine status.

Syntax:

KF<cr>

HEX = 4B 46 0D

Explain:

When the message of KF<cr> is sent to the power supply from
computer, the power supply will set the wheel knob to Fine status
immediately.

Example:

The present wheel knob status is at Normal, the KF<cr> message is

Advertising