Type of gas – American Dryer Corp. Gas/HSI & Steam ID-120 User Manual

Page 28

Advertising
background image

24

2. Technical Data

a. Gas Specifications

b. Gas Connections:

Inlet connection ------------------1-inch F.P.T.

Inlet supply size ------------------1-inch F.P.T. (minimum)

Btu/hr input (per dryer) ---------415,000 (104,580 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure

must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches

(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so

that the gas pressure must be regulated upstream of the dryer. The pressure measured at each

gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no

regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at

the source (L.P. tank) or an external regulator must be added to each dryer.

* Drill Material Size (D.M.S.) equivalents are as follows:

Natural Gas ................... #2 = 0.2210” (5.6134 mm).

Liquid Propane Gas ...... #30 = 0.1285” (3.2639 mm).

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

Shaded areas are stated in metric equivalents

TYPE OF GAS

Liquid

Propane

Conversion Kit

Part Number

ADC

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty.

D.M.S.*

Part

Number

Qty.

D.M.S.*

Part

Number

IDG-120

415,000

104,580

3

#2

140839

3

#30

140819

883118

Shaded area is stated in metric equivalent