- Analog Remote Setup

Analog Remote Settings: Reference input
(internal/external/external reference
level), protection limit (internal/external/
lesser limit), external mode (enable/dis-
able
)

%

- General Setup

Interface Settings: Data format (SCPI/
CIIL), GPIB address (default = 6), *RST
sets Output (on/off), Device clear (SCPI/
MATE), Serial Baud (Off/9600/19200),
Xon/Xoff (enable/disable), prompt (enable/
disable)

Max/Min Settings: Protect Entry (Bipolar/
Independent); for voltage mode: +Voltage
max, –Voltage min, ±CProtect max/min; for
current mode: +Current max, –Current
min, ±VProtect max/min

Load Type: Active/Resistive/Battery

Revisions/Test: (Tests: display, keypad,
interface, serial, analog and output)

Calibration: Voltage, Current and External
and Controls calibration

Power-up Settings: Mode (Voltage/Cur-
rent), Main channel reference (Internal/
External/External Reference Level), pro-
tect channel type (Internal/External/Lesser
Limit), Voltage Protect Limit (current
mode), Current Protect Limit (voltage
mode) output on/off

Password

Password Settings: Menu protection
(Interface/Max-Min/Load/Test/Power-
up/Keypad @ local/Keypad@power-
up), Save Display chg (Enable/Dis-
able
), Passwords (Main/Admin1/
Admin2 or Unprotected)

Series/Parallel: Configuration (Standalone/
Parallel/Series/Master 2X2/Master 3X2);
for parallel or series: Unit Type (Stand-
alone/Master+1 to+4/Slave #1 to #5) and
Connection Type: shows Series or Paral-
lel).

FIGURE 5. POWER-UP SCREEN SHOWING GRAPHIC METERS

HOW TO MODIFY A PARAMETER.
First access the parameter by accessing the proper
menu as described above. To modify a parameter
listed in a menu or submenu, proceed as follows:
1. Highlight the parameter using the

Y

and

U

keys.

2. When the desired choice is highlighted, press

!

to modify the active setting. The choices are dis-
played with the active setting highlighted. In the
case of numerals, the units digit is highlighted.

• To change a numeric setting, press the num-

ber keys, then press ENTER to program the
numbers entered. Use the CLEAR key to
clear numbers entered and start over. The
ADJUST control can also be used to incre-
ment or decrement the highlighted digit.

Pressing ADJUST while rotating adjusts the
least significant digit. If the output is on (unit
not in Standby) changes made using the
ADJUST control are immediately applied to
the output.

• For alphanumeric characters use multiple

presses of the number keys for letters or sym-
bols:

0

(space),

1

(+, –, /),

2

(ABC),

3

(DEF),

4

(GHI),

5

(JKL),

6

(MNO).

7

(PQRS),

8

(TUV),

9

(WXYZ). Use the

T

key to highlight the next character. As an alter-
native, the

U

or

Y

keys or ADJUST control

will scroll through numbers, and letters and
symbols. Use the CLEAR key to clear the
entire alphanumeric field and start over