B.25 [SOURce:]MEASure[:SCALar]:CURRent[:DC]? QUERY

MEAS:CURR?

Syntax:

Short Form: [SOUR:]MEAS[:SCAL]:CURR[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:CURRent[:DC]?
Returns: Measured values.

Description: Measures current. Measured value returned as XXX Amps, where XXX is decimal data representing

measured current.

B.26 [SOURce:]MEASure[:SCALar]:POWer[:DC]? QUERY

MEAS:POW?

Syntax:

Short Form: [SOUR:]MEAS[:SCAL]:POW[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:POWer[:DC]?
Returns: Measured values in the form 0.000 Kilowatts

Description: Measures power. Measured value returned as XXX Kilowatts, where XXX represents measured

power.

B.27 [SOURce:]MEASure[:SCALar]:VOLTage[:DC]? QUERY

MEAS:VOLT?

Syntax:

Short Form: [SOUR:]MEAS[:SCAL]:VOLT[:DC]?
Long Form: [SOURce:]MEASure[:SCALar]:VOLTage[:DC]?
Returns: Measured values in the form XXX Volts

Description: Measures voltage. Measured value returned as XXX Volts, where XXX is decimal data representing

measured voltage.

B.28 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude] COMMAND

COND

Syntax:

Short Form:[SOUR:]COND[:LEV][:IMM][:AMP] <NR2>
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude] <NR2>
Where <NR2> = conductance setpoint in Siemens

Description: Establishes conductance setpoint. Conductance setpoint affects the load only when the load is in

Conductance mode of operation. Conductance setpoint is stored in non-volatile memory; value is
restored upon power-up.

B.29 [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]? QUERY

COND?

Syntax:

Short Form:[SOUR:]COND[:LEV][:IMM][:AMP]?
Long Form: [SOURce:]CONDuctance[:LEVel][:IMMediate][:AMPlitude]?
Returns <NR2> = conductance setpoint in Siemens

Description: Indicates conductance setpoint.

B.30 [SOURce:]CONDuctance:TRANsient COMMAND

COND:TRAN

Syntax:

Short Form: [SOUR:]COND:TRAN <value>,<time>,<period>,<count>
Long Form: [SOURce:]CONDuctance:TRANsient <value>,<time>,<period>,<count>
Where:
<value> = <NR2> = the maximum conductance value of the transient (Siemans)
<time> = <NR2> = time (Seconds) from start to end of transient (0.0005 Second minimum)
<count> = <NR1> = number of times transient is to be repeated (default = 1, maximum = 65,000)
<period> (optional) = <NR2> = total time (Seconds) of repeating pulse train (must be at least 0.0005
greater than transient <time>)

Description: Configures a transient conductance pulse that is initiated by SYST:MODE:TRAN (see PAR.

B.100). See PAR. B.106 for details on using both Transient and Ramp commands at the same time.
Figure B-3 on page B-20 shows transient and ramp timing.