HSF 300W 050113

1

1.

INTRODUCTION

1.1

SCOPE OF MANUAL

This Operator's Manual covers the installation and operation of the Kepco HSF 300W Series of

Switching Power Supplies. For service information, write directly to: Kepco Inc., 131-38 Sanford

Avenue, Flushing, New York, 11355, U.S.A. Please state Model Designation and Serial Number of

your HSF Power Supply. This information can be found on the nameplate of the unit.

1.2

DESCRIPTION
The Kepco HSF 300 Watt Series are hot swappable, high frequency switching, plug-in power sup-

plies that are completely interchangeable with the metered HSF Series. Six models may be

selected for outputs of 5V, 12V, 15V, 24V, 28V or 48V. They employ forward conversion and power

factor correction and are designed to operate in a fault tolerant power system with a nominal a-c

input of 100V a-c to 240V a-c (input voltage range 85 to 265 Va-c), 50-60 Hz (input frequency

range 47-440Hz). A built-in current balancing circuit and OR-ing diodes allow configuration for

hot-swap and parallel-redundant N+1 operation.

These power supplies are designed to be used with Kepco's Series RA 19-4C rack adapters. The

RA 19-4C rack adapter accepts up to four 300W modules. All input/output connections are

through a 24-pin connector that plugs in to the rack adapter. All external connections described in

the following paragraphs are made through the rack adapter’s I/O connector (see Figure 1).

FIGURE 1. HSF REAR PANEL CONNECTOR AND RA 19-4C RACK ADAPTER I/O CONNECTOR

TABLE 1. HSF REAR CONNECTOR PIN ASSIGNMENTS

Signal

Name

Pin

Function

Output +

1, 2, 4

DC output (+) applied to load.

Output –

3, 5, 6

DC Output (–) applied to load.

SENSE–

7

Sense– connection

IMON+

8

Current Monitor+ (sense resistor).

SENSE+

9

Sense+ connection

NO

10

Normally Open contact of alarm relay, referenced to AL COM, pin 14 (see PAR. 3.7.2.1).

IMON–

11

Current Monitor– (sense resistor).

–COM

12

–Signal Common provides return for REF, pin 15, and RV, pin 18, signals.

NC

13

Normally Closed contact of alarm relay, referenced to AL COM, pin 14 (see PAR. 3.7.2.1).

AL COM

14

Common contact of alarm relay (see PAR. 3.7.2.1).

REF

15

Reference voltage. When used with RV, pin 18, allows all output voltages of paralleled slave supplies to be
controlled by one voltage adjustment of a master power supply. When REF is connected to RV via an
external trimmer, the external trimmer determines output voltage (see PAR. 3.4.2). Connections are made
via DIP switches (see PAR. 3.1).

3042951

8

9

7

12 11 10
15
18

16

17

14 13

21 20 19

2

1

3

4

5

6

22

23

24