Installation, 3 temperatures – KROHNE OPTIFLUX 6000 Quickstart EN User Manual
Page 15

INSTALLATION
2
15
OPTIFLUX 6000
www.krohne.com
07/2013 - 4002945701 - QS OPTIFLUX 6000 R05 en
2.9.3 Temperatures
Ambient temperature
Maximum process temperature
CAUTION!
Protect the device from direct sunlight.
°
C
°
F
min.
max.
min.
max.
Separate flow sensor
Compact version with;
IFC 050 , IFC100 & IFC 300
-40
65
-40
149
Type of connection
Separate flow sensor Compact + IFC 050
& IFC100
Compact + IFC 300
°
C
°
F
°
C
°
F
°
C
°
F
Aseptic weld on for pipes to
DIN 11850
140
284
120
1
248
2
140
284
Aseptic weld on for pipes to
ISO 2037
140
284
120
1
248
2
140
284
Dairy screw to DIN 11851
3
140
284
120
1
248
2
140
284
Screwed to SMS 1145
3
140
284
120
1
248
2
140
284
Flanges to DIN 11864-2A
140
284
120
1
248
2
140
284
Clamp joint to ISO 2852
120
248
120
248
120
248
Clamp joint to DIN 32676
140
284
120
1
248
2
140
284
Clamp joint to Tri Clamp
120
248
120
248
120
248
1 140°C if ambient temperature ≤ 40°C
2 284°F if ambient temperature ≤ 104°F
3 Without 3A mark