Electrical connections
For detailed information refer to the documentation of the relevant signal
converter.
Signal cable
Signal cable
Signal cable
Signal cable (remote versions only)
Type A (DS)
In combination with the IFC 050, IFC 100 and the IFC 300 signal converter
In combination with the IFC 050, IFC 100 and the IFC 300 signal converter
In combination with the IFC 050, IFC 100 and the IFC 300 signal converter
In combination with the IFC 050, IFC 100 and the IFC 300 signal converter
Standard cable, double shielded.
Max. length: 600 m / 1950 ft
(depends on electrical conductivity and measuring sensor).
For detailed information refer to the documentation of the relevant signal
converter.
Type B (BTS)
Only in combination with the IFC 300 signal converter
Only in combination with the IFC 300 signal converter
Only in combination with the IFC 300 signal converter
Only in combination with the IFC 300 signal converter
Optional cable, triple shielded.
Max. length: 600 m / 1950 ft
(depends on electrical conductivity and measuring sensor).
For detailed information refer to the documentation of the relevant signal
converter.
I/O
For full details of I/O options, including data streams and protocols, see
technical datasheet of the relevant converter.
Approvals and certificates
CE
CE
CE
CE
This device fulfills the statutory requirements of the EC directives. The
manufacturer certifies successful testing of the product by applying the CE
mark.
Electromagnetic
compatibility
Directive: 2004/108/EC
Harmonized standard: EN 61326-1 : 2006
Pressure Equipment
Directive
Not applicable: networks for the supply, distribution and discharge of water
and associated equipment are excluded from the scope of this directive.
Low voltage directive
Directive: 2006/95/EC
Harmonized standard: EN 61010 : 2001
Other approvals and standards
Other approvals and standards
Other approvals and standards
Other approvals and standards
Custody transfer
Only for DN25...300
Only in combination with the IFC 300 signal converter.
MID Annex MI-001 type examination certificate
Conformity with ISO 4064 and EN 14154
Innerstaatliche Bauartzulassung als Kältezähler (For Germany, Switzerland
and Austria)
Drinking water approvals
ACS, DVGW W270, NSF / ANSI Standard 61, TZW, WRAS
Protection category acc.
to IEC 529 / EN 60529
Standard:
Standard:
Standard:
Standard:
IP66 / 67 (NEMA 4/4X/6)
Option:
Option:
Option:
Option:
IP68 factory (NEMA 6P)
IP68 field (NEMA 6P)
IP68 is only available for separate design
Shock test
IEC 68-2-27
30 g for 18 ms
Vibration test
IEC 68-2-64
f = 20...2000 Hz, rms = 4.5 g, t = 30 min