Technical data – KROHNE WATERFLUX 3000 EN User Manual

Page 29

Advertising
background image

TECHNICAL DATA

6

29

WATERFLUX 3000

www.krohne.com

06/2013 - 400162663 - HB WATERFLUX 3000 R04 en

Electrical connections

For detailed information refer to the documentation of the relevant signal

converter.

Signal cable

Signal cable

Signal cable

Signal cable (remote versions only)

Type A (DS)

In combination with the IFC 050, IFC 100 and the IFC 300 signal converter

In combination with the IFC 050, IFC 100 and the IFC 300 signal converter

In combination with the IFC 050, IFC 100 and the IFC 300 signal converter

In combination with the IFC 050, IFC 100 and the IFC 300 signal converter

Standard cable, double shielded.

Max. length: 600 m / 1950 ft

(depends on electrical conductivity and measuring sensor).

For detailed information refer to the documentation of the relevant signal

converter.

Type B (BTS)

Only in combination with the IFC 300 signal converter

Only in combination with the IFC 300 signal converter

Only in combination with the IFC 300 signal converter

Only in combination with the IFC 300 signal converter

Optional cable, triple shielded.

Max. length: 600 m / 1950 ft

(depends on electrical conductivity and measuring sensor).

For detailed information refer to the documentation of the relevant signal

converter.

I/O

For full details of I/O options, including data streams and protocols, see

technical datasheet of the relevant converter.

Approvals and certificates

CE

CE

CE

CE

This device fulfills the statutory requirements of the EC directives. The

manufacturer certifies successful testing of the product by applying the CE

mark.

Electromagnetic

compatibility

Directive: 2004/108/EC

Harmonized standard: EN 61326-1 : 2006

Pressure Equipment

Directive

Not applicable: networks for the supply, distribution and discharge of water

and associated equipment are excluded from the scope of this directive.

Low voltage directive

Directive: 2006/95/EC

Harmonized standard: EN 61010 : 2001

Other approvals and standards

Other approvals and standards

Other approvals and standards

Other approvals and standards

Custody transfer

Only for DN25...300

Only in combination with the IFC 300 signal converter.

MID Annex MI-001 type examination certificate

Conformity with ISO 4064 and EN 14154

Innerstaatliche Bauartzulassung als Kältezähler (For Germany, Switzerland

and Austria)

Drinking water approvals

ACS, DVGW W270, NSF / ANSI Standard 61, TZW, WRAS

Protection category acc.

to IEC 529 / EN 60529

Standard:

Standard:

Standard:

Standard:

IP66 / 67 (NEMA 4/4X/6)

Option:

Option:

Option:

Option:

IP68 factory (NEMA 6P)

IP68 field (NEMA 6P)

IP68 is only available for separate design

Shock test

IEC 68-2-27

30 g for 18 ms

Vibration test

IEC 68-2-64

f = 20...2000 Hz, rms = 4.5 g, t = 30 min

Advertising