Temperature
>+75°C / +167°F
3
The ambient temperaure is
more than +75°C / +167°F.
This temperature is near to
the maximum limit for
device operation.
1
Measure the ambient temperature. De-
energize the device until the ambient
temperature is back in the given range. If
the temperature does not stay in the
correct range, make sure that there is
insulation around the signal converter.
1 This error message does not have an effect on the current output signal
INFORMATION!
In 4.0.0 MASTER menu, the type of error shown for error codes 102, 201 and 203 can be changed
from "Error" to "Warning" (the NE 107 status signal changes from "Failure" to "Out of
specification"). For more data, speak to the supplier.
Error
code
Error Message
Status
marker
shown
Cause
Corrective action