Supplementary Documentation BM 70 A, BM 70 P with PROFIBUS-PA


3. Menu settings for PROFIBUS-PA

(see Section 8.4 in the Installation and Operating Instructions)

The following settings need to be made for operation of the BM 70 A/P on a PROFIBUS-PA network. Note that the
service “set slave address” is not being supported. Therefore the address can only be set by way of the local display
and operator interface.

Function (Fct.) Input range

Default value Description

3.3.5 BAUDRATE

Select

31250 Bd.

31250 Bd.

If Fct. 3.3.7 is set to ”PROFIBUS”, the baud rate is
fixed at 31250 Bd.

3.3.6 ADDRESS

Input

0 ... 126

126

If Fct. 3.3.7 is set to ”PROFIBUS”, the default value
of the address is 126.

3.3.7 PROTOCOL

Select

HART

KROHNE/PC
PROFIBUS

PROFIBUS

Selection of the communications protocol.
Set to PROFIBUS when delivered.
(only when appropriate hardware provided)


4. Technical data,

PROFIBUS Ident-No. F901

Hardware
Physical

to IEC 61158-2 and the FISCO model

Bus characteristics 9... 30 V; 0.3 A max. ; 4.2 W max.
Base current

10 mA

FDE

yes: separate fault disconnection electronics
provided

Fault current

6 mA; (fault current = max. continuous
current – base current)

Starting current

lower than base current

”Ex” approval

EEx ia IIC T6 or EEx ib IIC/IIB T6 in
conformity with the FISCO model

Connection independent

of

polarity

Software
GSD

all KROHNE GSD files supplied on diskette

Device profile

complete implementation of Profile B, V2.0

Functional blocks level [m], distance [m], in addition volume [m

3

]

as cyclic value plus status
mentioned units are default units

Address range

0-126, default 126,
“set slave address” not supported

Operator control local display and operator interface at device
SAP`s

1; typically the number of service access points
is equal to the number of class 2 masters
(operating tools)