6 set up, 1 general, 2 adjustment elements – KROHNE OPTISWITCH 5100C Contactless EN User Manual
Page 19
6 Set up
6.1 General
The numbers in brackets refer to the following illustrations.
The switching condition of the electronics can be checked on
the plastic housing with closed housing cover (control lamp). In
the basic setting, products with a density >0.7 g/cm³
(>0.025 lbs/in³) can be detected. For products with lower
density, the switch must be set to >0.5 g/cm³ (>0.018 lbs/in³).
On the electronics module you will find the following indicating
and adjustment elements:
l
Signal lamp (1)
l
DIL switch for mode adjustment - A/B (2)
l
DIL switch for sensitivity adjustment (3)
Note:
For test purposes, immerse the tuning fork of OPTISWITCH
5100 C, 5150 C always in liquids. Do not test the function of
OPTISWITCH 5100 C, 5150 C with the hand. This can
damage the sensor.
6.2 Adjustment elements
1
2
1
2
3
Fig. 11: Oscillator SWE60C - Contactless electronic switch
1
Signal lamp (LED)
2
DIL switch for mode adjustment
3
DIL switch for sensitivity adjustment
Function/Configuration
OPTISWITCH 5100 C, 5150 C - with contactless electronic switch
19
Set up
30428
-EN