KROHNE PROFIFLUX IFS 5000 EN User Manual

Page 3

Advertising
background image

3

Items included with supply

IFS 5000 F
primary head

•

primary head
in the size as ordered

•

certificate of calibration data

•

installation material as specified
in the following table

•

installation instructions

IFM 5010 K, IFM 5020 K and IFM 5080 K
compact flowmeters

•

compact flowmeter
in the size as ordered

•

certificate of calibration data

•

installation material as specified
in the following table

•

installation instructions

•

installation and operating instruc-
tions for the signal converter

Flowmeter

Scope of supply ...

X = Standard

O = Option

Size of
measuring
tube

to ...

Pipe flanges

Meter sizes

Pressure rating

flange class

max. allowable
operating
pressure

1)

bar psig

... with
centering
material

... with
stud bolts

... with 2)
grounding
rings E and
gaskets ...

D1 D1+D2

... without 2)
grounding
rings but with
gaskets D3
and wires V

... DIN 2501 (BS 4504)

... ANSI B 16.5

DN

00

2.5 – 10

DN

0

15

DN

0

25

DN

0

40

DN

0

50

DN

0

80

DN 100

000

DN

0

10, 15

DN

0

15

DN

0

25

DN

0

40

DN

0

50

DN

0

80

DN 100

PN 40

PN 40

PN 40

PN 40

PN 40

PN 40

PN 16

PN 25

≤

40

≤

40

≤

40

≤

40

≤

40

≤

40

≤

16

≤

25

2

x

ring

2

x

ring

2

x

ring

4

x

sleeve

4

x

sleeve

6

x

sleeve

6

x

sleeve

6

x

sleeve

4

x

M12

4

x

M12

4

x

M12

4

x

M16

4

x

M16

8

x

M16

8

x

M16

8

x

M20

X

X

O

O

O

O

O

O

X

X

X

X

X

X

X

X

O

O

O

O

O

O

O

O

O

O

O

O

X

X

X

X

X

X

X

X

X

X

X

X

2

x

ring

2

x

ring

4

x

sleeve

2

x

ring

4

x

sleeve

4

x

sleeve

4

x

sleeve

4

x

sleeve

4

x

sleeve

6

x

sleeve

4

x

sleeve

6

x

sleeve

6

x

sleeve

6

x

sleeve

4

x 1

/

2

”

4

x 1

/

2

”

4

x 1

/

2

”

4

x 1

/

2

”

4

x 1

/

2

”

4

x 5

/

8

”

4

x 1

/

2

”

4

x 3

/

4

”

4

x 5

/

8

”

8

x 5

/

8

”

4

x 5

/

8

”

8

x 3

/

4

”

8

x 5

/

8

”

8

x 3

/

4

”

≤

20

≤

40

≤

20

≤

40

≤

20

≤

40

≤

20

≤

40

≤

20

≤

40

≤

20

≤

40

≤

20

≤

25

150 lb

300 lb

150 lb

300 lb

150 lb

300 lb

150 lb

300 lb

150 lb

300 lb

150 lb

300 lb

150 lb

300 lb

1

/

2

”

1

/

2

”

1”

1

1

/

2

”

2”

3”

4”

1

/

10

”–

3

/

8

”

1

/

2

”

1”

1

1

/

2

”

2”

3”

4”

1) For ANSI pipe flanges the max. allowable operating pressure is dependent on the process temperature,

see Sect. 10 “Technical data”.

2) For arrangement of gaskets and connection of wires V, see Section 7 “Grounding”.

≤

580

≤

580

≤

580

≤

580

≤

580

≤

580

≤

230

≤

360

≤

290

≤

580

≤

290

≤

580

≤

290

≤

580

≤

290

≤

580

≤

290

≤

580

≤

290

≤

580

≤

290

≤

360

Advertising