Installation instructions VARIFLUX 6000

7

5

Installation in the pipeline


• Installation material not included, to be provided by customer (stud bolts,

nuts, gaskets, etc.)


• Pipe connections, operating temperature and pressure:

refer to tables on “Limits” in Section 6.


• Fitting dimension

see Sect. 12 “Dimensions and weights”;


• High-temperature pipelines

Where process temperatures exceed 100 °C/212 °F, provide for facilities to compensate for
longitudinal expansion on heat-up of the pipeline.
For short pipelines use resilient gaskets and for long pipelines install flexible pipe elements
(e.g. elbows).



• Position of connections

Install flowmeter in line with the pipe axis. Pipe
connections must be parallel to each other, max.
permissible deviation:
L

max

- L

min

≤ 0.5 mm

≤ 0.02’’


• Torques


For flanged instruments
to DIN 11864-2a

Tighten down stud bolts and nuts
with max. torque:
32 Nm ~ 3.2 kpm ~ 23.5 ft x lbf

For all other connections
Tighten down to metal stop.