Ufc030 menu tree pdm menu bar – KROHNE UFC 030 PROFIBUS PA User Manual

Page 12

Advertising
background image

Supplementary documentation UFC030 with PROFIBUS-PA

KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5

D-47058 Duisburg

12/17

Tel.: 0203-301 309

Fax: 0203-301389 · e-mail: [email protected]

Attachment A

UFC030 Menu Tree PDM

Menu Bar

File

Device

View

Options

Help

Communication Path
-----------------------------------
Set Address
-----------------------------------
Load To Device
Load To PG/PC
-----------------------------------

Simulation

Test

-----------------------------------

Reset

-----------------------------------

Calibration

-----------------------------------

Set Time

Opt

-----------------------------------

Parameter Protection

Designations:

Opt

Optional, dependent on device

implementation / configuration

Rd

Read-only

Loc

Local PDM, affects only PDM views

2,3

FB1: AI -channel
FB2: AI - channel
FB3: TOT- channel
FB4: AI - channel

Opt

FB5: TOT- channel

Opt

Signal Converter

Input Simulation

•

Simulation

•

Simulation Value

•

Quality

•

Status

<Transfer>

Output Simulation

•

Target Mode

•

Output / AI

•

Quality

•

Status

•

Actual Mode

Rd

Signal Converter

•

Uncorrected Flow

•

VOS

•

Gain

•

Analog Input 1

•

Analog Input 2

•

Digital Input

<Start Simulation>

Inputs

•

<Test Analog Inputs>

Opt

•

<Test Digital Input>

Opt

Outputs

•

<Test Current O.>

O p t

•

<Test Frequency O.>

Opt

Communication Module

•

<Factory Reset>

•

<Warm Start>

•

<Reset Address to 126>

Signal Converter

•

<Quit Errors>

•

<Reset Totalizers>

•

<Cold Start>

Reset Device Parameters:

•

<Menu Parameters>

O p t

•

<Service Parameters>

Opt

•

<Calibration Params>

Opt

•

<All Parameters>

Opt

•

<Factory Parameters>

Opt

Zero Calibration

•

Zero Value 1 ... 5

Opt

•

<Zero Calibration>

Opt

Current Output Calibr.

Opt

•

Calibration 4 mA

Opt

•

Calibration 20 mA

Opt

•

<Calibrate Current O.>

O p t

Analog Input Calibr.

Opt

•

<Calibr. Anal. Inp. 1>

O p t

•

<Calibr. Anal. Inp. 2>

O p t

Measuring Path Calibr.

Opt

•

<Calibrate Path>

Opt

Parameter Protection

•

Parameter Protection

•

<Enable Write Prot.>

O p t

•

<Disable Write Prot.>

Opt

•

<Disable Service Parameter Protection>

Set Time

•

System Time

Opt

•

System Date

Opt

KROHNE UFC030 PA 45f50001 (1/6)
09.03

FB3: TOT- channel
• <Reset Totalizer>
• <Preset Totalizer>
• <Start Totalizer>
• <Reset Status>

O p t

FB5: TOT- channel

Opt

• <Reset Totalizer>
• <Preset Totalizer>
• <Start Totalizer>
• <Reset Status>

O p t