Ufc030 menu tree pdm parameter table – KROHNE UFC 030 PROFIBUS PA User Manual

Page 15

Advertising
background image

Supplementary documentation UFC030 with PROFIBUS-PA

KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5

D-47058 Duisburg

15/17

Tel.: 0203-301 309

Fax: 0203-301389 · e-mail: [email protected]

Identification

Operation Unit

Device

Signal Converter

-----------------------------------

Mask Bits for Diagnosis

Opt

-----------------------------------

Input

Low Flow Cutoff

Measuring Limits

Operation Parameter

-----------------------------------

Output

FB1: AI-channel

FB2: AI- channel

FB3: TOT- channel

FB4: AI- channel

Opt

FB5: TOT- channel

O p t

Local In-/Outputs

-----------------------------------

Mechanical Construction

Process Connection

-----------------------------------

Human Interface

Local Display

Operation Unit

•

Tag

•

Descriptor

•

Message

Measuring Limits

•

Mode

•

Range

Input

•

Tag

•

Static Revision No.

Rd

•

Zero Value

•

Flow Direction

Device

•

Manufacturer

Rd

•

Product Designation

Rd

•

Device Serial Number

Rd

•

Software Revision

Rd

•

Hardware Revision

Rd

•

Profile Revision

Rd

•

Static Revision Number

Rd

•

Profibus Ident Number

•

Installation Date

•

Write Locking

Rd

•

Parameter Protection

Rd

•

Device Variant

Rd

•

Firmware Ident Number

Rd

•

Function Select

Rd, Opt

•

Version

Rd

Identification

Designations:

O p t

Optional, dependent on device
implementation / configuration

Rd

Read-only

L o c

Local PDM,
affects only PDM views

UFC030 Menu Tree PDM

Parameter Table

Signal Converter

•

Manufacturer

Rd

•

Model Number

Rd

•

Serial Number

Rd

• µ

P2 HW No.

Rd

• µ

P2 SW No.

Rd

•

Front End HW No.

Rd

•

DSP HW No.

Rd

•

DSP SW No.

Rd

Low Flow Cutoff

•

Full Scale

Rd

•

Low Flow Cutoff

•

Cutoff On

Opt

•

Cutoff Off

Opt

Volume Flow

•

Unit

•

Lower Value Min

Rd

•

Upper Value Max

Rd

Sound Velocity

•

Unit

•

Lower Value Min

Rd

•

Upper Value Max

Rd

Corrected Volume Flow /
Heat Flow

O p t

•

Unit

•

Lower Value Min

Rd

•

Upper Value Max

Rd

Operation Parameter

•

GK Value

•

Converter Function

Plausibility Filter

•

Error Limit

•

Counter Decrement

•

Counter Limit

Sensor

Opt

•

Dead Time

•

Trigger Select

•

Sensor Frequency

•

Trigger Level 1

•

Trigger Level 2

Opt

•

Trigger Margin

Measuring Path

Opt

•

Select Path

•

Weight 1 ... 5

Opt

•

Length 1 ... 5

Opt

•

Zero Value 1 ... 5

Opt

•

Time Window Start

Opt

•

Time Window End

Opt

Analog Input

Opt

•

Input 1 0mA

•

Input 1 20mA

•

Input 2 0mA

•

Input 2 20mA

5

KROHNE UFC030 PA 45f50001 (4/6)
09.03