Bm102 menu tree ams – KROHNE BM 102 HART User Manual

Page 12

Advertising
background image

BM102 Remote Operation - HC 275 / AMS

Dev.-Rev. EC, DD-Rev. 01

© 2000 KROHNE SA 26103 Romans (France)

Page

12

Attachment B

(continued from the previous page)

Designations:
(L) - Local AMS variable, that is not read/written to
instrument
* - Read-only variable

Process Variables
Status
-----------------------------------
Diagnostics and Test
Calibrate
-----------------------------------
Master reset
Reset user EEPROM
Reset factory EEPROM
-----------------------------------
Entry Code
Service Code
-----------------------------------
Audit Trail
Drawing Notes ...
Help ...
-----------------------------------
Clear Offline Configuration
Compare Configurations
Configuration Properties

Basic Setup

•

Tag

----- Basic Functions -----

•

Tank Height

•

Probe Length

•

Dead Zone

•

Time Constant

---- Analog Output---------

•

Scale I1 Max

•

Scale I1 Min

---------- Sensor ------------

•

Snsr Upper Lim *

•

Snsr Lower Lim *

•

Snsr Min Span *

Sensor
------------ Tank-------------

•

Tank Height

•

Dead Zone

----------- Limits -----------

•

Snsr Upper Lim *

•

Snsr Lower Lim *

•

Snsr Min Span *

-------- Correction ---------

•

Detection Delay

Process Input

•

Length Unit

•

Volume/Mass/Flow Unit

•

Time Constant

------ Optional Unit ------

•

Unit Name

•

Unit Factor

------ Display format ------
------ (AMS screens) -------

•

Level format (L)

•

Volume format (L)

Analog Output
----- Analog 0utput---------

•

Function I

•

Range I

•

Error Delay

•

Scale I Max

•

Scale I Min

•

AO Alarm type *

HART
-- Device Identification --

•

Tag

•

Device ID *

•

Date

•

Descriptor

•

Message

•

Final Assembly Number

•

Sensor Serial Number

------ Protocol Data ------

•

Universal revision *

•

Num request preams *

•

Num response preams

•

Polling address

Service
---- Basis Parameters -----

•

Offset of Measure

•

Probe Type

•

Application Type

•

Epsilon R

------- Calibration ---------

•

Elec. Cal. Speed

•

Mech. Cal. Speed

•

Converter Value

----- Identification ---------

•

French Comm. Nmb.

•

German Comm. Nmb.

Device

•

Model *

•

Manufacturer *

•

Fld dev rev *

•

Software rev *

•

Write protect *

--------- User Data ---------

•

Serial Number *

•

French Comm. Nmb. *

•

German Comm. Nmb. *

•

Release Number *

•

ROM checksum *

•

Probe Type *

Strap Table

•

Number of points

20 pairs
Level " Volume/Mass/Flow

KROHNE BM102 45ec 01

BM102 Menu Tree AMS

Application
------- Threshold ----------

•

Level Signal Amplitude *

•

Level Signal Gain *

•

Distance value *

•

Threshold

Advertising