42 BATCHCONTROL

Object

No

Index

Value (def

ault)

D

esc

ri

pti

on

D

imensi

on

For

mat

min

max

access

Desc

ripto

r

transfe

r

Desc

ript

ion

0 = activation of
message output

3095H Statistic

3095H

00H

15

Number

of

entries

without

byte - - r - -

3095H 01H

-3000 Range 1

µl

Word

-32700 32700

r/w

-

d

First limit

3095H 02H

-1500 Range 2

µl

Word

-32700 32700

r/w

-

d

Second limit

3095H 03H

-500 Range 3

µl

Word

-32700 32700

r/w

-

d

Third limit

3095H 04H

+500 Range 4

µl

Word

-32700 32700

r/w

-

d

Fourth limit

3095H 05H +1500 Range 5

µl

Word

-32700 32700

r/w

-

d

Fifth limit

3095H 06H +3000 Range 6

µl

word

-32700 32700

r/w

-

d

Sixth limit

3095H 07H

0

Total number of fillings without

word

0

65535

r/w

-

d

Total number of fillings since the
last reset

3095H 08H

0

Number of fillings 1

without

word

0

65535

r/w

-

d

Number of fillings with a volume
lower than range 1

3095H 09H

0

Number of fillings 2

without

word

0

65535

r/w

-

d

Number of fillings with a volume
between range 1 and range 2

3095H 0AH

0

Number of fillings 3

without

word

0

65535

r/w

-

d

Number of fillings with a volume
between range 2 and range 3

3095H 0BH

0

Number of fillings 4

without

word

0

65535

r/w

-

d

Number of fillings with a volume
between range 3 and range 4

3095H 0CH

0

Number of fillings 5

without

word

0

65535

r/w

-

d

Number of fillings with a volume
between range 4 and range 5

3095H 0DH

0

Number of fillings 6

without

word

0

65535

r/w

-

d

Number of fillings with a volume
between range 5 and range 6

3095H 0EH

0

Number of fillings 7

without

word

0

65535

r/w

-

d

Number of fillings with a volume
higher than range 6

3095H 0FH

0

Reset statistic

without

byte

0

1

r

-

d

Bit 0: 1 = reset all statistic results

30AxH CAN parameter

30A1H 00H

7

Baudrate

without

byte

0

7

r/w

-

as

Bit 0 – 3:

0000

=

1MBaud

0001

=

800kBaud

0010

=

500kBaud

0011

=

250kBaud

0100

=

125kBaud

0101

=

100kBaud

0110

=

50kBaud

0111

=

20kBaud

30A2H 00H 127 Node

ID

without

byte

1

127 r/w

-

as

30A3H 00H

0 Customer

TPDO

activation

without

byte

0

15

r/w

-

d

Bit 0: 1 = customer TPDO1 activ
(description see below)

Bit 1: 1 = customer TPDO2 activ
(description see below)

Bit 2: 1 = customer TPDO3 activ
(description see below)

Bit 3: 1 = customer TPDO4 activ
(description see below)

30A4H 00H

0 Customer

RPDO

activation without

byte

0

15

r/w

-

d

Bit 0: 1 = customer RPDO1 activ
(description see below)

Bit 1: 1 = customer RPDO2 activ
(description see below)

Bit 2: 1 = customer RPDO3 activ
(description see below)

Bit 3: 1 = customer RPDO4 activ
(description see below)

32yxH Customer specific 1 bit memory (3 <= y <= 8)

32y1H

00H

8

Number

of

entries

without

byte - - r - -

32y1H 01H

0 Bit

no

1

without

byte

0

1

r/w

-

d

1. bit variable (this parameter use
the same memory cell as 30y2.04)

32y1H 02H

0 Bit

no

2

without

byte

0

1

r/w

-

d

2. bit variable (this parameter use
the same memory cell as 30y2.04)

32y1H 03H

0 Bit

no

3

without

byte

0

1

r/w

-

d

3. bit variable (this parameter use
the same memory cell as 30y2.04)

32y1H 04H

0 Bit

no

4

without

byte

0

1

r/w

-

d

4. bit variable (this parameter use
the same memory cell as 30y2.04)

32y1H 05H

0 Bit

no

5

without

byte

0

1

r/w

-

d

5. bit variable (this parameter use
the same memory cell as 30y2.04)

Advertising