TECHNICAL DATA

24

OPTIFLUX 5000

www.krohne.com

04/2011 - 4000686302 - HB OPTIFLUX 5000 FL R02 en

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

Compact version: -40...+140°C / -40...+284°F

Remote version: - 40...+180°C / -40...+356°F

For Ex versions different temperatures are valid.

Please check the relevant Ex documentation for details.

Maximum temperature

change (shock)

120°C / 248°F

Ambient temperature

-40…+65°C / -40…+149°F

For Ex versions different temperatures are valid.

Please check the relevant Ex documentation for details.

Storage temperature

-50…+70°C / -58…+158°F

Pressure

Pressure

Pressure

Pressure

Ambient

Atmospheric

Nominal flange pressure

Standard:

Standard:

Standard:

Standard:

EN 1092-1

DN200...300: PN10

DN100...150: PN16

DN15...80: PN40

ASME B16.5

Standard:

Standard:

Standard:

Standard:

1...12": 150 lb

½

": 300 lb

Option:

Option:

Option:

Option:

1...3": 300 lb

Vacuum load

0 mbar / 0 psi

Pressure ranges for

secondary containment

Pressure resistant up to 40 bar / 580 psi

Burst pressure up to approx. 160 bar / 2320 psi

Chemical properties

Chemical properties

Chemical properties

Chemical properties

Physical condition

Conductive liquids

Electrical conductivity

Non water:

Non water:

Non water:

Non water:

DN25...300: ≥ 1 μS/cm

DN15: ≥ 5 μS/cm

Demineralised cold water:

Demineralised cold water:

Demineralised cold water:

Demineralised cold water:

DN15...300: ≥ 20 μS/cm

Permissible gas content

(volume)

≤ 5%

Permissible solid content

(volume)

IFC 100: ≤ 10%

IFC 300: ≤ 70%

Recommended flow

velocity

-12...+12 m/s / -40...+40 ft/s

Installation conditions

Installation

Take care that the flow sensor is always fully filled.

For detailed information refer to

Installation

on page 10.

Flow direction

Forward and reverse.

Arrow on flow sensor indicates positive flow direction.

Advertising