Electrical connections, 2 limit switch – KROHNE DK 46-47-48-800 EN User Manual

Page 16

Advertising
background image

4

ELECTRICAL CONNECTIONS

16

DK46 - DK800

www.krohne.com

05/2011 - 4000302403 MA DK46-800-R03-en

4.2 Limit switch

The flowmeters can be equipped with a maximum of two limit switches. The switching function of
the limit switch can be designed as monostable or bistable.

Monostable function:

Switching pulse as float passes through switching point,
independent of direction of movement.

Bistable function:

Stable changeover as float passes through switching point.

Example (bistable):

Float above limit: Output "High"
Float below limit: Output "Low"

For switching patterns and electrical connection values of different limit switches, see -
Technical Data - Limit Switches

Connection of limit switch - 2 wire NAMUR

1 Lower limit switch to terminal 1
2 Upper limit switch to terminal 2

The connection box includes an EMC filter unit.

Electrical connection limit switches - 2-wire NAMUR no terminal box

1 Limit switch (no terminal box)
2 Blue cable -
3 Brown cable +
4 External EMC filter
5 Receiver device

When connecting to an EMC filter, the ground terminal must be connected to the back rail of the
flowmeter.

Electrical connection limit switch - 3-wire (transistor)

bn - brown: supply voltage +
bk - black - switch
bu - blue: supply voltage -

MA_DK46_800_R03_en_302403_PRT.book Page 16 Thursday, May 19, 2011 8:26 AM

Advertising