START-UP

5

21

DK46 - DK800

www.krohne.com

05/2011 - 4000302403 MA DK46-800-R03-en

Start-up

5.1 Start-up

CAUTION!
When starting up the flowmeter, the following points must be observed:
•

Compare the actual operating pressure and the process temperature of the system with the
specifications on the nameplate (PS and TS); these limits must not be exceeded.

•

Make sure materials are compatible.

•

Close the needle valve at the flowmeters.

•

Slowly open the shut-off valve upstream and downstream of the flowmeter.

•

When measuring liquids, vent the pipes carefully.

•

When measuring gases, increase pressure slowly.

•

void float impact (e.g. caused by solenoid valves), as this is likely to damage the measuring
section or float.

•

Open needle valve at the flowmeters and set the required flow rate.

•

The top edge of the float marks the reading line for flow values:

Figure 5-1: Reading edge

1 Reading edge
2 Floatform AIII
3 Floatform ball