4.3 Limit switch settings
4.3.1 Limit switch settings MS14
• Undo bracket screw 1 and set switching position
• Secure bracket screw 1
The distance between the limit switch and the casing is factory set with clamp screw 2 so that
the limit switch touches the glass taper at the maximum switching point.
The limit switch must be rotated 180° to reach the lower range of the scale.
4.3.2 Limit switch settings TG21
• Undo bracket screw 1 and set switching position
• Secure bracket screw 1
The distance between the limit switch and the casing is factory set at approx. 1 mm (0.039") with
the clamping screw 2.