Technical data – KROHNE GA 24 EN User Manual
Page 22
6
TECHNICAL DATA
22
GA24
www.krohne.com
02/2011 - 4001229901 MA GA24 R01 en
Limit switch use
Technical Data Limit Switches
Size
Cone no.
Limit switch
Size
Cone no.
Limit switch
DN15
N 18.07
MS14/A
DN25
N 21.09
MS14/A
TG21
N 18.09
MS14/A
N 21.13
MS14/A
TG21
N 18.13
MS14/A
N 21.18
MS14/A
TG21
N 19.09
MS14/A
N 21.25
MS14/A
TG21
N 19.13
MS14/A
DN40
N 41.09
MS14/A
TG21
N 19.19
MS14/A
N 41.13
MS14/A
TG21
N 19.26
MS14/A
N 41.19
MS14/A
TG21
DN50
N 51.10
MS14/A
TG21
N 51.15
MS14/A
TG21
N 51.21
MS14/A
TG21
Technical data MS14
Contact type
Normally open or normally closed, can be reconnected
Switching reproducibility
< 2% of full-scale range
Contact rating
12VA
max. turn-on voltage
30VDC
Max. switching current
0,5A
Ambient temperature
-20...+85°C / -4...+185 °F
Protection category acc. to IEC 60529 / EN
529
IP44
Technical data TG21
Rated voltage
8VDC
Current consumption, active surface open
3mA
Current consumption, active surface
covered
1mA
Ambient temperature
-25...+100°C / -13...+212 °F
Protection category acc. to IEC 60529 / EN
529
IP 67 (NEMA 6)