Technical data – KROHNE OPTIMASS 1000 EN User Manual
Page 35
TECHNICAL DATA
6
35
OPTIMASS 1000
www.krohne.com
04/2011 - 4000977901 - MA OPTIMASS 1000 R01 en
OPTIMASS 1300C T6 - aluminium
converter housing - no heating jacket /
insulation
40
45
T6
T80
60
T5
T95
100
T4
T130
130
T3 - T1
T155
50
60
T5
T95
100
T4
T130
130
T3 - T1
T160
60
60
T4 - T1
T95
65
1
65
T4 - T1
T100
OPTIMASS 1300C T6 - aluminium
converter housing - heating jacket /
insulation
40
45
T6
T80
60
T5
T95
95
T4
T130
130
T3 - T1
T165
50
60
T5
T95
95
T4
T130
100
T3 - T1
T135
60
60
T4 - T1
T95
65
1
65
T4 - T1
T100
OPTIMASS 1300C T6 - Stainless Steel
converter housing - no heating jacket /
insulation
40
45
T6
T80
60
T5
T95
100
T4
T130
130
T3 - T1
T155
50
60
T5
T95
100
T4
T130
130
T3 - T1
T160
55
55
T4 - T1
T95
OPTIMASS 1300C T6 - Stainless Steel
converter housing - heating jacket /
insulation
40
45
T6
T80
60
T5
T95
95
T4
T130
120
T3 - T1
T155
50
60
T5
T95
75
T4 - T1
T110
55
55
T4 - T1
T130
1 depending on I/O option. Please call for more information.
Ambient temp.
Tamb °C
Max. medium
temp. Tm °C
Temp. class
Max. surface
temp. °C
MA_OPTIMASS_1000_en_110401_4000977901_R01.book Page 35 Friday, April 1, 2011 1:41 PM