Installation – KROHNE OPTIMASS 2000 EN User Manual
Page 21

INSTALLATION
3
21
OPTIMASS 2000
www.krohne.com
10/2010 - 4000810002- MA OPTIMASS 2000 R02 en
Maximum end loadings
• These (axial) loads have been calculated, based on 316L schedule 80 process pipework,
where un-radiographed butt welds have been used in pipe joints.
• The loads shown are the maximum permitted static load. If loads are cycling (between
tension and compression) these loads should be reduced. For advice, consult the
manufacturer.
3.4.7 Pipework reducers
Always avoid extreme step changes in pipe size. Use pipework reducers, where there is a large
difference between pipework size and meter flanges.
3.4.8 Flexible connections
S100
S150
S250
Flanges
Flanges
Flanges
Flanges
20°C
40 barg
150kN
350kN
550kN
100 barg
100kN
120kN
60kN
150 barg
180 barg
130°C
32 barg
150kN
280kN
400kN
80 barg
60kN
50kN
50kN
115 barg
130 barg
Hygienic (all connections)
Hygienic (all connections)
Hygienic (all connections)
Hygienic (all connections)
130°C
10 barg
5kN
-
-