Technical data, 3 guidelines for maximum operating pressure – KROHNE OPTIMASS 3000 EN User Manual
Page 31
TECHNICAL DATA
6
31
OPTIMASS 3000
www.krohne.com
03/2012 - 4001593001 - MA OPTIMASS 3000 R01 en
6.3 Guidelines for maximum operating pressure
Notes
• Ensure that the meter is used within its operating limits
• All hygienic process connections have a maximum operating rating of 10 barg at 130°C /
145 psig at 266°F
Pressure / temperature de-rating for all meter sizes / materials, in metric
Pressure / temperature de-rating for all meter sizes / materials, in metric
Pressure / temperature de-rating for all meter sizes / materials, in metric
Pressure / temperature de-rating for all meter sizes / materials, in metric
X Temperature [°C]
Y Pressure [barg]
1 Hastelloy
®
C22 measuring tube
2 Stainless Steel 316L measuring tube
3 Outer casing