BM 26 A construction details
The diagram below shows a standard BM 26 A/C/RR without level transducer and switch options
1 Vent
plug
2 Measuring
tube
3
Red triangle reference mark giving
factory-calculated zero position of
measuring scale
4
Glass tube for indicator
5 Scale
6
Float (magnets mounted in lower half)
7 Liquid
level
8
Mid-point of indicator
9
Indicator (standard follower bar)**
10
Zero point of measurement
(centreline of lower connecting flange)
11 Scale
zero
12
Stop (red KROHNE plate)
13 Instrument
nameplate
* optional flap indicator available (see section 8)
Details:
Item 12 – The red KROHNE plate at the bottom of the scale (item 5) has a label listing the product
and the operating conditions. For example :
Working pressure :
Working temperature :
Density :
Fluid :
6 bar g
25 C
0.778 s g.
cyclohexane