TECHNICAL DATA

8

43

BW25

www.krohne.com

09/2010 - 4000432302 MA BW25 R05 en

8.2 Technical data

INFORMATION!
•

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.

•

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Level measurement

Operating method / measuring principle

Displacement principle

Measured value

Level, separating layer

Measuring accuracy

Standard

< 1.5% full scale value

Min. measuring range

0.3 m / 12"

Max. measuring range

6 m / 20 ft

Medium

Liquids

Density

≥ 0.45 kg/l / 28.1 lbs/ft

3

Materials

Housing

Aluminium with artificial resin coating

Housing option

Stainless steel (indicator M9)

Displacer rod

Stainless steel 1.4404

Displacer rod option

Titanium

Spring

Stainless steel 1.4571 (T

m

< 100°C / 212°F)

Spring option

ATS 340 (T

m

> 100°C / 212°F)

Flange

Stainless steel 1.4404

Pressure sleeve

Stainless steel 1.4404

Process connections

Max. operating pressure

40 bar - optional to 400 bar / 580 - optional 5802

psig

Standard flange

DN50 - PN40 / 2" ASME 300 lbs

Optional flange

...DN100 - ...PN400 / …4" ASME ...2.500 lbs

Approvals

ATEX, indicator M9 with electrical installations

Cat. II 1/2G, EEx ia IIC T6

ATEX, indicator M10

Cat. II 1/2G, EEx d IIC T6

ATEX, indicator M9 without electrical installations

for Zone 0 tanks

Cat. II 1/2 Gc

for Zone 1.21

Cat. II 2 GD

for Zone 2.22

Cat. II 3 GD

MA_BW25_R05_en_432302_PRT.book Page 43 Tuesday, September 28, 2010 8:17 AM