Technical data, Ifc 070 flow converter functions, Design – KROHNE OPTIFLUX 2070 EN User Manual
Page 31: Cable connections, Materials, In- and output, Power supply, Approvals

TECHNICAL DATA
8
31
OPTIFLUX 2070
www.krohne.com
04/2008 • 4000243601
IFC 070 flow converter
Functions
Flow direction
Bi-directional measurement
Low flow cut-off
Selectable
Design
Display
8 digits LCD
Status indication for battery, diagnostics
Units
m
3
, US Gallons
m
3
/h, USGPM
Cable connections
Standard
2x M20 x 1,5
Optional
1/2" NPT, PF 1/2
Materials
Converter housing
Die-cast aluminium (polyurethane coated)
In- and output
Outputs
2 passive pulse outputs for remote totalising
f ≤ 500 Hz; I ≤ 10 mA; U: 5...24 VDC (P ≤ 100 mW)
2 passive status outputs
I ≤ 10 mA; U: 5...24 VDC (P ≤ 100 mW)
Power supply
Standard
2 lithium batteries (D-cell), typical lifetime 6 years.
Alarms
Pre-alarm 1 year before battery depletion and final alarm
Battery replacement
Possible without loss of totaliser data
Approvals
Protection class
IP 66/67 (NEMA 4X/6)