KROHNE CORIMASS G-MFM 4085 EEx EN User Manual
Page 10
10
Ensure that the screw thread of the round cover on the terminal box is well greased at all times.
–
NOTE: The grease used must be non corrosive to aluminium; typically it must be resin-
and acid free.
– Protect
the
sealing ring from damage.
11 12
- + DC
Coding of the
Outputs acc. to following PE
Table:
Term.
No.
Variant G
(1 current,1
puls
intrins.safe)
Variant H
(1 current, 1
status output.
intrins.safe)
Variant K
(1 current, 1
control inp.
intrins.safe)
Term.
No.
Variant L
(2 current,
intrins.safe)
Term.
No.
Variant M
1current, 1
Bus
intrins.safe)
I 1
current output
(+)
current output
(+)
current output
(+)
I 1
current
output 1
(+)
I 1
current output
1
(+)
I 1
current output
(-)
current output
(-)
current output
(-)
I 1
current
output 1
(-)
I 1
current output
1
(-)
B
puls output (+)
status output.
(+)
control input.
(+)
I 2
current
output 2
(+)
D
Bus
B
puls output (-)
status output. (-
)
control input. (-)
I 2
current
output 2
(-)
D
Bus
Please note,that the power supply terminals are behind a lid. To connect, shift lid upwards,