KYORITSU 2002R User Manual

Page 17

Advertising
background image

― 40 ―

6−3−2 Continuity Check

①

Set the function selector switch to the "

Ω

/ "

position.

②

Slide the terminal cover to the left. Plug the red test lead into the V/

Ω

terminal and the black test lead into the COM terminal.

③

Press the mode switch to set the instrument to the continuity check
mode. The measuring range is fixed to 400

Ω

and the "

" symbol

is shown on the display.

④

Short the tip of the test leads and make sure that the display reads
"0" and the buzzer beeps.

⑤

Connect the tip of the test leads to the circuit under test. The
display reads the resistance and the buzzer beeps when the
reading is not more than about 50

Ω

.

NOTE

●

When shorting the tip of the test leads, the display may read a very
small resistance instead of "0". This is the resistance of the test
leads, not a fault.

●

If one of the test leads is open, the display reads "OL".