9.Optional Accessories
●
Multi-Tran MODEL 8008 extends the capability of MODEL 2002PA
or MODEL 2002R, allowing measurement up to 3000A or on a
large bus-bar or conductor.
①
Set the function selector switch to "
∼
400A".
②
As shown in the figure below, clamp MODEL 2002PA or MODEL
2002R onto the pickup coil of MODEL 8008.
③
Clamp MODEL 8008 onto the bus-bar or conductor under test.
④
Take the reading on MODEL 2002PA or MODEL 2002R and
multiply it by 10.