3−2 MODEL 2002R
●

Measuring Ranges and Accuracy(at 23

±

5

℃

, relative humidity 45-75%)

AC Current

∼

400

A,

∼

2000

A

(9 counts or less is corrected to 0)

Range

400

A

2000

A

Measuring Range

0∼

400.0

A

0∼

1000

A

1000

∼

1500

A

1500

∼

2000

A

Measuring Range

0∼

40.00

V

15.0

∼

400.0

V

150

∼

750

V

Measuring Range

0∼±

40.00

V

±

15.0

∼±

400.0

V

±

150

∼±

1000

V

Measuring Range

0∼

400.0

Ω

0.150

∼

4.000k

Ω

1.50

∼

40.00k

Ω

15.0

∼

400.0k

Ω

Output Voltage / Measuring Range

0∼

400.0

mV

/

0∼

400

A

0∼

150.0

mV

/

0∼

1500

A

150.0

∼

200.0

mV

/1500

∼

2000

A

Resolution

0.1

A

1A

Resolution

0.01

V

0.1

V

1V

Resolution

0.01

V

0.1

V

1V

Resolution

0.1

Ω

1Ω

10

Ω

100

Ω

Accuracy

(

Frequency Range

)

±

1.5%rdg

±

3dgt

(

45

∼

65Hz

)

±

2.5%rdg

±

3dgt

(

40

∼

1kHz

)

±

2.0%rdg

±

5dgt

(

45

∼

65Hz

)

±

3.0%rdg

±

5dgt

(

40

∼

1kHz

)

±

4.0%rdg

(

50/60Hz

)

Accuracy

(

Frequency Range

)

±

1.0

%

rdg

±

2dgt(45

∼

65Hz)

±

1.5

%

rdg

±

3dgt(40

∼1

kHz)

Accuracy

±

1.0

%

rdg

±

2dgt

Accuracy

±

1.5

%

rdg

±

2dgt

Accuracy

(

Frequency Range

)

±

2.0%rdg

±

0.5mV

(

45

∼

65Hz

)

±

3.0%rdg

±

0.5mV

(

40

∼

1kHz

)

±

2.5%rdg

±

0.5mV

(

45

∼

65Hz

)

±

3.5%rdg

±

0.5mV

(

40

∼

1kHz

)

±

4.5%rdg

(

50/60Hz

)

Maximum Measurement Time

Continuous

15min

5

min

Range

40

V

400

V

750

V

Range

40

V

400

V

1000

V

Range

400

Ω

4k

Ω

40k

Ω

400k

Ω

Range

400

A

2000

A

AC Voltage

(

∼

V)

Auto-ranging

(9 counts or less is corrected to 0)

Initially set to the 40V range. Input impedance is about 1M

Ω

.

When approx.300V or more is applied to the instrument instantaneously, the measured
value is indicated on 750V range.

DC Voltage

(

V)

Auto-ranging

Initially set to the 40V range. Input impedance is about 1M

Ω

.

Resistance(Auto-ranging)

Initially set to the 400

Ω

range. In the continuity check mode, fixed to the 400

Ω

range and

when the reading is not more than 50

±

35

Ω

, the buzzer beeps.

OUTPUT(

AC Current Ranges

)

DC Output: 100.0mV per 1000 counts (Output impedance: about 10k

Ω

)

●

CF (Crest Factor) CF=3 or less
accuracy+1% (45

∼

65Hz)

、

less than AC3000A/AC1200V Peak

●

Electromagnetic compatibility (EMC)
EN61000-4-2 Electrostatic discharge immunity(ESD)
Performance criteria B

Advertising