KYORITSU 3007A User Manual

Page 8

Advertising
background image

IEC 60529 (IP54)

Dust & drip proof

●

Operating System:

Dual integration

●

Display:

Liquid crystal display (maximum count: 1999),

Unit, Mark

Bar graph 30 points max. (20 points on

Ω

range)

●

Over range Indication:

"OL" is shown on the display.

●

Sample Rate:

Approx. 0.5 ~ 2.5 times per second

●

Operating Temperature 0 ~ +40

°

C, relative humidity up to 85%

& Humidity:

●

Storage Temperature

-20 ~ +60

°

C, relative humidity up to 75%

& Humidity:

●

Insulation Resistance:

More than 50M

Ω

at 1000V DC between electrical

circuit and housing case

●

Withstand Voltage:

3700V AC for one minute between electrical

circuit and housing case

●

Overload Protection

Insulation resistance ranges:

1000V Range

1200V (DC+AC p-p) for 10 seconds

500V Range

600V (DC+AC p-p) for 10 seconds

250V Range

300V (DC+AC p-p) for 10 seconds

Continuity ranges:

20/200/2000

Ω

280V (DC+AC p-p) for 10 seconds

Range

(Protection by fusing)

―

7

―

●

Typical Number of Measurements.

(central tendency for supply voltage up to 8V)

Insulation Resistance Ranges:

Approx. 1000 times min. at load 0.5M

Ω

Continuity Ranges:

Approx. 700 times min. at load 1

Ω

●

Operating Errors (IEC 61557-2,-4)

Functions

Range

Measuring range to keep

Maximum percentage

operating error

operating error

20M

Ω

0.50 ~ 19.99M

Ω

1000V

200M

Ω

1.0 ~ 199.9M

Ω

2000M

Ω

10 ~ 1000M

Ω

20M

Ω

0.50 ~ 19.99M

Ω

500V

200M

Ω

1.0 ~ 199.9M

Ω

2000M

Ω

10 ~ 100M

Ω

20M

Ω

0.25 ~ 19.99M

Ω

±

30%

250V

200M

Ω

1.0 ~ 199.9M

Ω

2000M

Ω

10 ~ 100M

Ω

20

Ω

0.20 ~ 19.99

Ω

Ω

200

Ω

1.0 ~ 199.9

Ω

2000

Ω

10 ~ 1999

Ω

The influencing variations used for calculating the operating error are

denoted as follows;

Temperature:

0

℃

and 35

℃

Supply voltage :

8V to 13.8V

●

Applicable Standards

IEC 61010-1

Over voltage CAT III 300V Pollution Degree 2

IEC 61010-2-31

Safety requirements for hand-held probe

assemblies

IEC 61557-1/2/4

Measuring equipment for low voltage

distribution systems

IEC 61326-1

EMC

―

6

―

3007A-E 01.9.12 11:52 AM ページ 6