KEW6310

Basic Setting 

KEW6310

−

11 −

Basic Setting

Setting item

Details of Setting

Wiring

①

1P2W×1

②

1P2W×2

③

1P2W×3

④

1P2W×4

⑤

1P3W×1

⑥

1P3W×2

⑦

1P3W×1+2A

⑧

3P3W×1

⑨

3P3W×2

⑩

3P3W×1+2A

⑪

3P3W3A

⑫

3P4W×1

⑬

3P4W×1+1A

⓪

4A

Voltage Range

150V╱

300V╱600V╱1000V

VT Ratio

0.01~9999.99(1.00)

Clamp / Current Range

8128:1╱5╱10╱20╱50A╱AUTO

8127:10╱20╱50╱100A╱AUTO

8126:20╱50╱100╱200A╱AUTO
8125:50╱100╱200╱500A╱AUTO

8124:100╱200╱500╱1000A╱AUTO

8129:300╱1000╱3000A

8141:

8142:

}

100╱500mA╱1A╱AUTO

8143:

8146:

8147:

}

500mA╱1╱5╱10A╱AUTO

8148:

CT Ratio

0.01~9999.99( 1.00 )

Filter

8141╱42╱43╱46╱47╱48:ON╱OFF
8128╱27╱26╱25╱24╱29: --------

DC V

50mV╱500mV╱ 5V

Frequency

50Hz╱60Hz

            

* Default values are highlighted in gray

            

* Leakage Clamp sensors cannot be used for power measurements but can be used on

wiring configurations: ⑦, ⑩, ⑬ and ⓪.