Martel Electronics 320 User Manual
Page 53
Advertising
ELECTRICAL: ±(%FS, ±1 LSD)
Standard Units:
Range Units
%FS
Res.
0-10
V
0.025
0.001
0-30
V
0.1
0.01
0-20
mA
0.025
0.001
0-50
mA
0.1
0.01
CSA Approved / Intrinsically Safe Units:
Range Units
%FS
Res.
0-10
V
0.05
0.001
0-30
V
0.1
0.01
0-20
mA
0.05
0.001
0-50
mA
0.1
0.01
IMPEDANCE:
Volts
1 MegaOhm
mA
25 Ohms
RESOLUTION: 50,000 counts maximum, depending
on range (see accuracy table) and engineering unit
(see appendix B).
TEMPERATURE:
Operating: 0 to 50ºC (No Effect on Accuracy within
this range.)
51