Color lead wire & color display label – Revo RECDH2812-1 User Manual

Page 6

Advertising
background image

2. Color Lead Wire & Color Display Label

2

3. Power : power source from a DC 12V / AC24V +/- 10%

Use Certified/Listed Class 2 power supply transformer only.

*If use DC 12V / AC24V power adaptor, use the power consumption 5W over.

REMINDER:
Never aim the
camera directly
into the sun.

COLOR

RED

WHITE

YELLOW

GRAY

BLACK

DESCRIPTION

AC24V/DC12V
AC24V/DC12V

ALARM OUT

DN EXT-IN

DN EXT-OUT

GND

BLACK&WHITE

4. Video : BNC connector used to connect the camera to a monitor, switcher, etc.

CO

LO

R

RE

D

W

HIT

E

YE

LL

O

W

G

RA

Y

BL

AC

K

DE

SC

RIP

TIO

N

AC

24

V/D

C1

2V

AC

24

V/D

C1

2V

AL

AR

M

O

UT

DN

E

XT

-IN

DN

E

XT

-O

UT

G

ND

BLA

CK

&W

HIT

E

5. DAY&NIGHT I/O Terminals

To select Day/Night mode using external equipment, connect control lines

to the appropriate terminals.

DAY&NIGHT OUTPUT

It is the function that can turn on external IR LED Lamp by detecting the sensitivity on

the AGC level when the D&N mode is set "AUTO" on the OSD menu of the camera.

DAY&NIGHT EXTERNAL INPUT

It is the function that can be switched to DAY Mode or NIGHT Mode by receiving the

D&N on/off signal from external light sensor or IR LED LAMP. When D&N Mode is set

"External" on the OSD menu of the camera.

6. ALARM OUT

Motion detection signals are output through this port. (On High (5V))

DN EXT-OUT

GND

5V/10mA : IR LED ON(NIGHT)

0V : IR LED OFF(DAY)

GND

DN EXT-IN

Open contact : DAY

Close contact : NIGHT

Advertising