Alarm – Revo RELPTZ22-3 Advanced Features User Manual

Page 17

Advertising
background image

REVO America

www.revoamerica.com

RELPTZ22-3

15

5. You can also overwrite the programmed number and to remove a stored number from the

Tour. Press the HOME key on the stored number, a blank position mark (---) will be
displayed.

6. Repeat steps 2 through 5 for each desired Preset position. Each title will be displayed on

top of the line.

7. To create a unique title, refer to the

Titling procedure.

8. Select SAVE AND EXIT and move the joystick to the right. Press

the ESC key

to exit the

program without saving.

9. To store the Tour that you created as the default programmed action for the camera,

navigate to the DOME SETUP menu and select HOME FUNCTION. Refer to the

Home

Function procedure.

Alarm

The Alarm Setup menu enables you to set alarm inputs and outputs to and from the camera.

ALARM SETUP

NO PRI FUN IN OUT HLD LATCH

01 1 001 NO ON 03 OFF

02 1 --- OFF OFF 03 OFF

DWELL : 03

ALARM OUT SETUP

SAVE AND EXIT(ESC TO CANCEL)


NO:


There are two inputs Alarm available.

PRI:

The input Alarm has a priority of 1.

FUN:

Function. Stored Preset number to be called by alarm.

IN:

Input. Specifies the type of input that will trigger the alarm.
NO: Normally open.
NC: Normally closed.
OFF: Ignore input.