Seametrics MJ-Series User Manual

Page 3

Advertising
background image

U.S. GALLONS

20mm

40˚C

X100

X10

X1

X0.1

X0.01

Page 3

U.S. GALLONS

25mm

40˚C

X1

X0.1

U.S. GALLONS

25mm

40˚C

X100

X10

X1

X0.1

Setting Your Pulse Rate.

The pulse rate is determined by which

sensor was ordered from the factory (single reed switch, dual

reed switch, or single Hall-effect) and by the dial on which the

magnet pointer is located. The pointer is set at the factory, but

can be changed in the field as follows.

In the table below: 1) Locate your meter size (Column 1); 2)

Find your desired pulse rate (Column 2); 3) Note the magnet

pointer position (Column 3); 4) Move the magnet pointer to

the appropriate dial position (using the detailed instructions

below the table); 5) Use the appropriate Connection Diagram

(from Column 4) to wire the sensor to your remote device (using

diagrams on page 4).

CHANGING PULSE RATES

1” Meter

100 Gal/Pulse

x10 Gal Dial

(reads 6x10)

1” Meter

100 Gal/Pulse

Magnet Pointer

x10 Dial

(10 x 10=100 G/P)

Pulse

Rate

Magnet Pointer

Dial Position

Connection

Diagram #

*20 P/G

2

10 P/G

1
1

*2 P/G

x0.1

x0.1

1 P/G

x0.1

3/4"

*5 G/P

x1

2

10 G/P

x1

1

*50 G/P

x10

2

100 G/P

x10

1

*2 P/G

x0.1

2

1"

1-1/2"

2"

1 P/G

x0.1

1

*5 G/P

x1

2

10 G/P

x1

1

*50 G/P

x10

2

100 G/P

x0.1
x0.1

1

*2 P/G

2

1 P/G

1

*5 G/P

x1

2

10 G/P

x1

1

*50 G/P

x10

2

100 G/P

x0.1
x0.1
x0.1

1

*2 P/G
1 P/G
*5 G/P

x1

2

10 G/P

x1

1

*50 G/P

x10

x10

2

100 G/P

x10

1

*These pulse rates available in MJR and MJHR dual reed switch meters only.
†This pulse rate available in MJR and MJHR single reed switch meters only.

2

1

2
1

x0.01

x0.01

Meter

Size

†4 P/G

1

x0.1

†4 P/G

†4 P/G

x0.1

1

†4 P/G

1

x10

Moving the Magnetic Pointer.

Remove meter top and lens,

taking care not to lose the sealing ring. With fingers, lift the

magnet pointer off its shaft and remove the plain pointer from

the target dial. Reverse their positions and press them firmly

into place. Securely seat the sealing ring and replace the lens,

matching the tab on the lens to the notch on the meter to align

the sensor with the magnetic pointer dial. Thread the meter top

on and tighten.

†NOTE:

A special magnet (available from the factory) is required

to achieve a rate of 4 pulses per gallon. It should be placed on

the x0.1 dial, with non-magnetic pointers on the remaining dials.

Otherwise, the procedure is the same.

Sample Set-Up.

A 1” meter is shown with the magnet

pointer set at the x10 dial, with a pulse rate of 100 Gal-

lons per Pulse (that is, 10 increments on the x10 dial, or

10x10=100 Gal/Pulse).

x1 Gal Dial

(reads 2x1)

x0.1 Gal Dial

(reads 4x0.1)

Six-Digit Totalizer

(reads 138x100)

X10

Reading Your Meter.

The Total Flow that has passed

through your meter is read by starting at the top of the reg-

ister with the Six-Digit Totalizer, and then reading clockwise

around the small dials. In the example below, the Six-Digit

Totalizer reads 13,800 (138 x 100), and the dials read 60

(6 x 10), 2 (2 x 1), and .4 (4 x .1) respectively. The Total

Flow is 13,862.4 gallons.

U.S. GALLONS

25mm

40˚C

X100

X10

X1

X0.1

Col. 1

Col. 2

Col. 3

Col. 4

[With the magnet pointer

on the x1 dial, the pulse

rate would be 10x1=10

Gal/Pulse. With the mag-

net pointer on the x0.1 dial,

the pulse rate would be

10x.1=1 Gal/Pulse.]

Special Configurations.

The 3/4” meter has a fourth dial,

as shown above. The x0.01 dial is

used for 20 P/G and 10 P/G rates.

Note: The 3/4” meter has a 5 digit

totalizer.

The 4 P/G rate requires

a special magnet, placed

on the x0.1 dial, as shown

above.

(NOTE: Disregard the color of the numbers on the totalizer when reading

your total.)

The “ones” digit is significant but the fact that it is red is not significant.

1 3 8

X100

Advertising